Radioflex 300EG S3

Radioflex 300EG-S3 (ceramic X-ray tube)
6032S3

Features
1. An extended variable range of the tube voltage has broadened the application ranging from thin plate to thick plate testing. .
2. Digitisation of the timer {LED display) enhances the reproducibility of the exposure time and facilitates settings in dimly lighted spaces.
3. Automatic ageing system. The ageing display lamp does not light when ageing is already over or not required {automatic memory circuit).
4. The tube current is always maintained at 5 ma by automatic adjustment.
5. A 100% Duty Cycle for continuous use.
 

Radioflex 200EG-S3

Output:

160 - 300kV (160 - 240kV in 10KV steps ) (240 -3OOkV in 5kV steps)
Automatically adjusted to 5mA (constant)

Filter:

AI 2.0mm

Penetration:
(iron thickness}

54mm (Fuji # 100, lead foil intensifying screen PbO.03, 5 min.)
63mm (Fuji # 100, metallic fluorescent intensifying screen SMP-308. 5 min.}
88mm (Fuji # 400, metallic fluorescent intensifying screen SMP-308, 5 min.) Film density D = 1.5

Power supply:

100 -240V single phase AC 5O/60Hz 2.2kV A

Focus size

2.5x 2.5mm

Dimensions:

Generator 737 x 320 x 320mm (handle included}
Controller 420 x 395 x 245mm (handle included)

Weight:

Generator 38.5kg
Controller 25kg