Radioflex 250EG-S3

Radioflex 250EG-S3 (ceramic X-ray tube)
6029S4

Features
1.An extended variable range of the tube voltage has broadened the application ranging from thin plate to thick plate testing.
2.A special electronic circuit is incorporated to ensure a quicker response to source voltage fluctuations.
3.Digitisation of the timer (LED display) enhances the reproducibility of the exposure time and facilitates settings in dimly lighted spaces.
4.The remainder of the pre-set exposure time is memorised in case of power failure during operation.
5.Automatic ageing system. The ageing display lamp does not light when ageing is already over or not required (automatic memory circuit).
6.The tube current is always maintained at 5 ma by automatic adjustment.
7.Whether or not the source voltage is appropriate can be known at a glance.
8.Intermittently continuous operation is possible.
9.A remote controller is available as an option.

 

Output:

110 ~250kV 110 ~130kV in 10kV steps
130 ~ 250kV in 5kV steps
Automatically adjusted to 5mA (constant)

Filter:

AI 2.0mm

Penetration:
(iron thickness}

42mm (Fuji # 100, lead foil intensifying screen PbO.03, 5 min.)
56mm (Fuji # 100, metallic fluorescent inten- sifying screen SMP-308, 5 min.)
82mm (Fuji # 400 , metallic fluorescent inten- sifying screen SMP-308, 5 min.)
Film density D= 1.5
 

Power supply:

190 ~ 240V single phase AC 50/60Hz 3.6kV A

Focus size

2.0 x 2.0mm

Dimensions:

Generator 632 x 320 x 320mm (handle included)
Controller 355 x 345 x 240mm (handle included)

Weight:

Generator 29kg
Controller 17kg